Difference between revisions of "Firmware-73 Message-111"
(Created page with "==COM (111, 6Fh)== This message contains the COM port status of the USB-microDig. See the DUMP COM command for more information. The [BODY] of the COM message is as follows:...") |
|||
| (One intermediate revision by the same user not shown) | |||
| Line 1: | Line 1: | ||
| − | ==COM (111, 6Fh)== | + | ==COM STATUS (111, 6Fh)== |
| − | This message contains the COM port status of the USB-microDig. See the DUMP COM command for more information. | + | This message contains the COM port status of the USB-microDig. See the [[Firmware-73_Command-111 |DUMP COM STATUS command]] for more information. |
| − | The [BODY] of the COM message is as follows: | + | The [BODY] of the COM STATUS message is as follows: |
{| | {| | ||
Latest revision as of 03:56, 20 November 2016
COM STATUS (111, 6Fh)
This message contains the COM port status of the USB-microDig. See the DUMP COM STATUS command for more information.
The [BODY] of the COM STATUS message is as follows:
| 00000xyz: | x = 0; DTR high |
| x = 1; DTR low | |
| y = 0; RTS low | |
| y = 1; RTS high | |
| z = 0; SUSP low (USB enabled) | |
| z = 1; SUSP high (USB disabled) |